Panel style
Diameter of rainproof bearing:diameter of 20000.60mm; edge sharp: 40o ~ 45 o
The resolution of the:0.2mm
Accuracy of measurement:indoor artificial rainfall, to the instrument itself displacement of quasi
Level of accuracy:less than 2%
Accuracy of secondary:less than 3%
Three kinds of precision:less than 4%
Rainfall intensity range:0.01mm ~ 4mm/min (to allow the maximum rainfall intensity 8mm/min)
Output signal:double contact point off signal output
The work environment:the environment temperature: -20 to 50 DEG C; relative humidity; <95% (40 DEG C)
Dimension:Phi 216 * 480 2.2Kg