What happens when the coil polarity of the relay is reversed?
date:2021-02-18 17:30:49reading:

It will not cause failure or damage to the relay itself, but will affect the coil, resulting in the following conditions.

Single stabilizer relay: inactive.

Single-winding latching relay: reversed SET and RESET action

Double winding latching relay: depending on the type of relay used, it may cause malfunction or stop operation.

When using latching relays, some relays are configured in such a way that the contacts are in a reset state when a reverse polarity voltage is applied to the set coil. When a reverse polarity voltage is applied to the reset coil, the contacts are in the set state, but the relay cannot be used in this manner, regardless of the design.